GE DS3800HSQD1J1E 50 线带状电缆连接到电路板

GE DS3800HSQD1J1E 50 线带状电缆连接到电路板品牌GE加工定制否额定功率要求+5 VDC: 1.0 A (USB满载0.5 A时可达1.5 A)工作温度0至60C(32F至140F)执行速度0.072毫秒每1000布尔指令时钟精度每天最大漂移2秒实时时钟电池预计寿命5年嵌入式串行通信Rs-232 (com1) rs-485 (com2)支持的串行协议Modbus RTU Sla

立即咨询立即咨询

咨询电话 :17359299796

微信:17359299796邮箱:A3669372910@163.com

产品详情

 GE DS3800HSQD1J1E 50 线带状电缆连接到电路板

品牌
GE
加工定制
额定功率要求
+5 VDC: 1.0 A (USB满载0.5 A时可达1.5 A)
工作温度
0至60°C(32°F至140°F)
执行速度
0.072毫秒每1000布尔指令
时钟精度
每天最大漂移2秒
实时时钟电池
预计寿命5年
嵌入式串行通信
Rs-232 (com1) rs-485 (com2)
支持的串行协议
Modbus RTU Slave, SNP Slave, Serial I/O
底板
双背板总线支持:RX3i PCI和90-30式串行
程序块
最多512个程序块
最多512个程序块
%I和%Q: 32Kbits用于离散
可售卖地
全国

 GE DS3800HSQD1J1E 50 线带状电缆连接到电路板

产品描述


GE 低 HP 序列板DS3800HSQD设计为每个角上都有一个孔,用于插入螺钉以将板固定在驱动器中。GE 低 HP 序列板DS1HSQD还配备了 3800 个 2 针连接器和 40 个带固定杆的 1 针连接器,用于固定带状电缆。该板还装有 20 针连接器和 50 个 1 针连接器。该板还装有 20 个可擦除可编程只读存储器 (EPROM) 模块和 1 个琥珀色指示灯 LED 和 1 个红色指示灯 LED。


50 针连接器用于将 50 线带状电缆连接到电路板。带状电缆的布线必须允许空气带走电路板组件的热量。如果带状电缆连接到 50 针连接器,请整齐地折叠电缆,并将电缆穿过电路板并沿驱动器内侧布线。从那里,可以在不干扰气流的情况下布线电缆。


断开 50 线带状电缆时必须特别小心。细线股由电缆承载的 50 个控制信号组成。它们很脆弱,很容易与电缆末端连接的塑料连接器断开连接。最佳做法是永远不要对带状电缆施加压力,因为这可能会导致电线与连接器分离。用一只手牢牢握住连接器,然后轻轻地将其从连接器上取下。如果拉扯带状电缆以断开其连接,则可能会损坏带状电缆。

IS230TBAIH2C.jpg

 GE DS3800HSQD1J1E 50 线带状电缆连接到电路板

Product description


The GE Low HP serial board DS3800HSQD is designed with a hole in each corner for inserting screws to secure the board in the drive. The GE Low HP serial board DS1HSQD also comes with 3,800 2-pin connectors and 40 1-pin connectors with fixed rods for securing ribbon cables. The board is also equipped with 20-pin connectors and 50 1-pin connectors. The board is also equipped with 20 erasable programmable read-only memory (EPROM) modules and one amber LED and one red LED.


The 50-pin connector is used to connect the 50-wire ribbon cable to the circuit board. The wiring of the ribbon cable must allow air to carry away the heat of the board components. If the ribbon cable is connected to a 50-pin connector, fold the cable neatly and route the cable through the circuit board and along the inside of the driver. From there, the cable can be routed without interfering with the airflow.


Special care must be taken when disconnecting 50 ribbon cables. The thin strand consists of 50 control signals carried by the cable. They are fragile and easily disconnected from the plastic connectors attached to the end of the cable. The best practice is to never apply pressure to the ribbon cable, as this can cause the wire to separate from the connector. Hold the connector firmly with one hand and gently remove it from the connector. If you pull the ribbon cable to disconnect it, you may damage the ribbon cable.