1B30035H01 EMERSON艾默生 输入输出模块 DCS卡件品牌EMERSON艾默生原厂地美国性能全新最大功率10-240VDC频率1000Hz接口8通道转速100m/s重量2.8lb货期库存现货可售卖地北京;天津;河北;山西;内蒙古;辽宁;吉林;黑龙江;上海;江苏;浙江;安徽;福建;江西;山东;河南;湖北;湖南;广东;广西;海南;重庆;四川;贵州;云南;西藏;陕西;甘肃;青海;宁夏;新疆
产品详情
1B30035H01 EMERSON艾默生 输入输出模块 DCS卡件
1B30035H01 EMERSON艾默生 输入输出模块 DCS卡件
操作员站采用DELL 公司的商用机 , 交换机采用的是CISCO 的产品。该DCS以其支持带电插拔、简洁易用、功能强、组态方便、接线容易等诸多特点深受工控人的喜爱。CCPP采用了冗余Ovation DCS VWestinghouse西屋3.3.1,采用C/S结构,注册码授权,通讯协议采用以太网TCP/IP。
CCPP涉及煤气、蒸汽和发电机组,都是对安全要求极高的设备。稍有不慎,轻则会出现机组退出,严重者会出现爆炸事故。来不得半点马虎。为此,针对CCPP这样的工艺特点,在下载前,必须做好充分的事故应急预案工作,制订切实有效的安全防范措施,如将该控制器控制的所有重要运行设备,如运行允许全部切换为就地运行,所有通讯点进行隔离,并将与其对应控制器有联锁关系点和不同控制器机柜的硬接线点强制,防止新旧程序在下装瞬间,回到执行状态时的初始扫描过程中,软件初始值引起失控状态值输出,导致设备误动作。
为此,Westinghouse西屋程序下装工作尽量选择在机组停运期间,采用相对安全的增量下装方式,少用全下装。总之,现场调试时的程序下装思维不能照搬照抄到生产运行中,因为现场调试属于模拟运行,而生产过程中是带负荷运行。
1B30035H01 EMERSON艾默生 输入输出模块 DCS卡件
The operator station uses DELL commercial machines, and the switch uses CISCO products. The DCS is favored by industrial controllers for its support for live plugging, simple and easy to use, strong functions, convenient configuration, easy wiring and many other features. CCPP adopts redundant Ovation DCS VWestinghouse 3.3.1, C/S structure, registration code authorization, and Ethernet TCP/IP communication protocol.
CCPP involves gas, steam and generator sets, all of which have high safety requirements. A little careless, light will appear unit exit, serious will appear explosion accident. There must be no carelessness. To this end, in view of the process characteristics such as CCPP, before downloading, it is necessary to make adequate accident emergency plan work and formulate effective safety precautions, such as all important operating equipment controlled by the controller, such as operation allows all to be switched to local operation, and all communication points are isolated. And force the interlocking relationship points of its corresponding controller and the hard wiring points of different controller cabinets to prevent the initial scanning process when the old and new programs return to the execution state at the moment of installation, the initial value of the software will cause the output of the out-of-control status value, resulting in device misoperation.
To this end, the Westinghouse process downloading work should be selected as far as possible during the outage of the unit, using a relatively safe incremental downloading method, and using less full downloading. In short, the program installation thinking during field debugging cannot be copied to the production operation, because the field debugging belongs to the simulation operation, and the production process is run with load.